B1 STRUCTURE ACCEPTABLE SOLUTION B1/AS1
Definitions
Term Definition
and shrinking, frost heave, changing ground water level, erosion, dissolution
of soil in water, and effects of tree roots.
COMMENT: Soils (excepting those described in (a), (b) and (c) above)
tested with a dynamic cone penetrometer in accordance with
NZS 4402 Test 6.5.2, shall be acceptable as good ground for building
foundations if penetration resistance is no less than:
a) 5 blows per 100 mm at depths down to twice the footing width.
b) 3 blows per 100 mm at depths greater than twice the footing width.
Depths shall be measured from the underside of the proposed
footing.
Non-combustible Material that meets the criteria for a non-combustible material in
Section 8.1 of the Building Product Specifications.
Territorial Authority means a city council or district council named in Part 2 of Schedule 2 of the
(TA) Local Government Act 2002; and—
a) in relation to land within the district of a territorial authority, or a building
on or proposed to be built on any such land, means that territorial authority;
and
b) in relation to any part of a coastal marine area (within the meaning of the
Resource Management Act 1991) that is not within the district of a territorial
authority, or a building on or proposed to be built on any such part, means
the territorial authority whose district is adjacent to that part.