G4 VENTILATION ACCEPTABLE SOLUTION G4/AS1
Ventilation options for typical apartment layouts
Figure C.1.1.1A: Layout 1
Paragraph C.1.1.1
Internal wall
External
wall
BEDROOM
6m max for Paragraph 2.2.2.2
Internal
wall
External
wall
6m max for Paragraph 2.2.2.2 and Paragraph 2.4.2.1(d)(ii)
Openable
10 m max for Paragraph 2.4.2.1(d)(i)
windows
and
LIVING ROOM trickle
ventilators
in external
wall
OPEN
BATHROOM KITCHEN
Internal wall
Table C.1.1.1A: Ventilation options – Layout 1
Paragraph C.1.1.1
Natural Mechanical Combined
Room
ventilation ventilation ventilation
Bedroom Paragraph 2.2.2.2 Section 2.3 –
2.4.2.1(d)(ii) (6 m max distance) or
Living room Paragraph 2.2.2.2 Section 2.3
2.4.2.1(d)(i) (10 m max distance)
Paragraphs 2.4.2.1(d)(ii) (6 m max distance) or
Kitchen Section 2.3
2.2.2.2 and 2.2.2.3 2.4.2.1(d)(i) (10 m max distance)
2.4.2.1(d)(ii) (6 m max distance) or
Bathroom Paragraph 2.2.2.2 Section 2.3
2.4.2.1(d)(i) (10 m max distance)