Skip to content

New Zealand · Acceptable Solution

G4/AS1: Ventilation

Acceptable Solution for natural and mechanical ventilation within the scope of clause G4.

Ventilation
Open original PDF at page 21

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

G4 VENTILATION ACCEPTABLE SOLUTION G4/AS1 Ventilation options for typical apartment layouts Figure C.1.1.1C: Layout 3 Paragraph C.1.1.1 Internal wall External wall 6m max for Paragraph 2.2.2.2 KITCHEN LIVINGROOM Internal wall 6m max for Paragraph 2.2.2.2 and Paragraph 2.4.2.1(d)(ii) 10 m max for Paragraph 2.4.2.1(d)(i) External wall Openable windows and BATHROOM BEDROOM trickle ventilators 6m max for Paragraph 2.2.2.2 in external wall Internal wall Table C.1.1.1C: Ventilation options – Layout 3 Paragraph C.1.1.1 Natural Mechanical Combined Room ventilation ventilation ventilation Bedroom Paragraph 2.2.2.2 Section 2.3 – 2.4.2.1(d)(ii) (6 m max distance) or Living room Paragraph 2.2.2.2 Section 2.3 2.4.2.1(d)(i) (10 m max distance) 2.4.2.1(d)(ii) (6 m max distance) or Kitchen – Section 2.3 2.4.2.1(d)(i) (10 m max distance) 2.4.2.1(d)(ii) (6 m max distance) or Bathroom – Section 2.3 2.4.2.1(d)(i) (10 m max distance) MINISTRY OF BUSINESS, INNOVATION AND EMPLOYMENT 28 JULY 2025 Page 21

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.