I oJuwy 8, 2024 OFFICIAL GAZETTE 7193
re nes
E provided, however, that means of an elevator with a
where the primary function minimum door opening width
can be served at the ingress of 900 mm;
level and where such level 3. When the space allotted
is provided with facilities, for the primary function will
requirements for accessibility not be diminished by more
at other levels may be than ten percent (10%) of its
waived. original area;
2. Ten percent (10%) of the 4. When the capacity or strength
total number of units of of any major structural
government-owned living component, such as slabs,
accommodations shall be beams, girders, columns,
accessible and fully usable by bearing walls, and footings of
the persons with disabilities the building or structure will
with any fractional part in not be diminished;
excess of one-half (1/2) in 5. When the cost (exclusive
the computation thereof, to of the exception provided
be considered as one unit: below) of such repair or
for privately-owned living renovation work is in excess
accommodations the number of twenty percent (20%) of
of accessible units shall be the total cost of the building
as provided in Section 3 of or structure, based upon the
Rule Ill thereof. computation of permit fees
3. Ingress/egress from the as provided under Rule Ill of
street to the building or the Implementing Rules and
structure shall be accessible. Regulations promulgated
4. Accessible slots in parking pursuantto P.D. 1096 entitled:
areas shall be located as "The National Building Code
near as possible to ingress/ of the Philippines";
egress spaces of the building 6. When there is no legal
or structure. constraint that would not
ii. Buildings and related structures allow compliance with these
to be repaired or renovated, regulations:
including those proposed 7. EXCEPTION: Repair . or
for a change of occupancy If renovation work that consists
feasible, barrier-free facilities and only of heating, ventilating,
accessibility features shall be and air conditioning systems,
provided in accordance with the including those which may
requirements under Sub-section be required only with respect
4.1.1 (1), (c) and (d): feasibility to fire panic and explosion
of incorporation of barrier- safety for existing spaces,
free facilities and accessibility shall not be subject to the
features shall be determined from requirements for barrier-free
all the following conditions: facilites and accessibility
1. When the repair or renovation features.
work is to be done in the iii.
space where the primary 1. Streets, highways, and
function is served; transport-related structures
2. When the facilites can be to be constructed -Streets,
made accessible at any other highways, and transport-
level, which is accessible by related structures shall be
056960—18
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.