Philippines · Implementing rules
BP 344: 2024 revised accessibility rules
The revised implementing rules for BP 344, including accessibility provisions for ramps, entrances and facilities.
- Edition
- 2024 revised IRR
- Search coverage
- 16 of 16 PDF pages · 16 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 6 OCR transcription · 92% recognition confidence. Compare dimensions and tables with the original page.
Jury 8, 2024 OFFICIAL GAZETTE 7195
the National Building Code, and the Fire Code consideration are the dimensions
is mandatory. In cases of conflict, consult with of wheelchairs, the minimum
Building Officials or authorities responsible space needed for locking and
for code enforcement for clarification. unlocking leg braces, and the
range of distance of crutches
RULE Il - MINIMUM REQUIREMENTS FOR and other walking aids from
ACCESSIBILITY persons using such devices. By
- Fenslis applying at this very early stage
bs Dosian Celteria; dimensional criteria that take
a. CATEGORIES OF PERSONS WITH into account wheelchair usage,
DISABILITIES. The categories of the physical environment will
disability dictate the varied measures ultimately encourage and enable
to be adopted in order to create an wheelchair users to make full use
accessible environment for persons of their physical surroundings.
with disabilities. Persons with iii. The provision of adequate space
disabilities under these Rules may be for wheelchair maneuvering
classified into those who have: generally ensures adequate
i. Physical mobility disabilities space for persons with disabilities
requiring the use of wheelchairs equipped with other technical aids
or or accompanied by assistants.
ii. Physical mobility disabilities In determining the minimum
causing difficulty in walking or dimensions for furniture and
climbing stairs or requiring the fixtures accessible to persons
use of braces, crutches, or other with disabilities, the following
artificial supports; or disabilities anthropometric data shall serve
caused by amputation, arthritis, as guides for design:
spastic conditions, or pulmonary, 1. The length of wheelchairs is
cardiac, or other ills rendering at least 1.10 m.
individuals semi-ambulatory; or 2. The width of wheelchairs is at
iii. Sensory Disabilities such as least 0.80 m.
individuals who are Deaf, have 3. Acircle of 1.80 m in diameter
hard of hearing, individuals who is a suitable guide in planning
are Blind or with low vision. wheelchair-turning spaces.
iv. Disabilities due to conditions of 4. The reach of wheelchair
aging and incoordination; users is:
Vv. Developmental, and Behavioral a. 0.7 m to 1.20 m above
or Emotional Disabilities the finished floor and not
b. ANTHROPOMETRICS AND less than 0.40 m from
DIMENSIONAL DATA AS GUIDES room corners for vertical
FOR DESIGN. The minimum and forward reach .
maximum dimensions for spaces in b. For obstructions at least
the built environment shall consider 500 mm in depth, the
the following criteria: maximum forward reach
i. The varying sizes and structures is 1.10 m above the
of persons of all sexes, their finished floor.
reaches, and their lines of sight c.05 m to 09 m for
at both the standing and sitting comfortable horizontal
positions. forward reach. The
ii. The dimensional data of the maximum horizontal
technical aids of persons with forward reach are as
disabilities. Included in the second follows:
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.