England · Statutory guidance
Access to and use of buildings: Approved Document M
Accessibility guidance for dwellings and buildings other than dwellings. The linked PDF is Volume 2.
- Edition
- PDF: Volume 2, 2015 edition incorporating 2020 and 2024 amendments
- Search coverage
- 74 of 74 PDF pages · 1 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 47 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
M1
FACILITIES IN BUILDINGS OTHER THAN DWELLINGS
e. pull cords for emergency alarm systems the boundaries of rooms or spaces, identify
are coloured red, located as close to access routes and receive information. For
a wall as possible and have two red example, glare and reflections from shiny
50mm diameter bangles, one set at surfaces, and large repeating patterns,
100mm and the other set between should be avoided in spaces where visual
800mm and 1000mm above the floor; acuity is critical as they will hamper
communication for people with impaired
f. controls that need close vision are
vision, and those who lip read or use sign
located between 1200mm and 1400mm
language. This would apply to locations
above the floor so that readings may be
such as reception areas with enquiry desks
taken by a person sitting or standing (with
and speakers’ rostrums in lecture halls.
thermostats at the top of the range);
4.33 The type and quality of public address,
g. socket outlets are located consistently
hearing enhancement and telephone
in relation to doorways and room
systems should be chosen carefully to
corners, but in any case no nearer
ensure intelligibility. The design of the
than 350mm from room corners;
acoustic environment should also ensure
h. light switches for use by the general
that audible information can be heard clearly.
public have large push pads and align
4.34 Artificial lighting should be designed
horizontally with door handles within
to give good colour rendering of all surfaces,
the range 900 to 1100mm, for ease of
without creating glare or pools of bright light
location when entering a room;
and strong shadows. Where appropriate,
i. where switches described in 4.30(h)
lighting should illuminate the face of a
cannot be provided, lighting pull cords
person speaking, to make lip reading
are set between 900mm and 1100mm
easier where one-to-one communication
above floor level, and fitted with a
is necessary. Uplighters mounted at low
50mm diameter bangle visually
or floor level can disorientate some visually
contrasting with its background and
impaired people and should be avoided.
distinguishable visually from any
4.35 In order to obtain the full benefit of
emergency assistance pull cord;
attending public performances or taking
j the operation of switches, outlets and
part in discussions, a person with impaired
controls does not require the simultaneous
hearing needs to receive a signal that is
use of both hands, except where this
amplified in both volume and signal to
mode of operation is necessary for
noise ratio. The three systems commonly
safety reasons;
used to provide this enhanced level of
k. switched socket outlets indicate sound are induction loop, infrared and radio.
whether they are ‘on’; Sound field systems are also increasingly
being used, particularly in educational
l. mains and circuit isolator switches
establishments. In larger spaces, provision
clearly indicate that they are on or off;
needs to be made for a permanent system,
m. front plates contrast visually with their but in small meeting rooms, a portable
backgrounds. induction loop would be acceptable. It
should be recognised that there is the
Aids to communication
danger where adjacent spaces each have
Design considerations an induction loop system that the signals
may overlap.
4.31 People will benefit most if there is an
integrated system for wayfinding, public Note: Detailed guidance on surface
address and hearing enhancement. finishes, visual, audible and tactile signs, as
well as the characteristics and appropriate
4.32 The appropriate choice of floor, wall
choice and use of hearing enhancement
and ceiling surface materials and finishes
systems, is available in BS 8300.
can help visually impaired people appreciate
Approved Document M Volume 2 Access to and use of buildings other than dwellings
O N L I N E V E R S I O N 45
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.