L1(a) O N L I N E V E R S I O N Limiting standards for new or replacement elements 4.5 New fabric elements should meet the limiting standards in Table 4.1. This includes all of the following. a. Elements in new buildings. b. New elements in extensions to existing buildings. c. New or replacement elements in existing buildings. Guidance on when a new or replacement element in an existing building must meet the requirements in this table is given in Section 10. 4.6 If windows or fully glazed pedestrian doors cannot meet the requirements of Table 4.1 in an existing building because of the need to maintain the character of the building, either of the following should be met. a. These fittings should not exceed a centre pane U-value of 1.2W/(m2·K). b. Single glazing should be supplemented with low-emissivity secondary glazing. 24 Approved Document L Volume 2, 2021 edition Building Regulations 2010 O N L I N E V E R S I O N