R28 O N L I N E V E R S I O N
Section 12: Consequential improvements
12.1 For an existing building with a total useful floor area of over 1000m2, additional work may be
required to improve the overall energy efficiency of the building if proposed work consists of or
includes any of the following.
a. An extension.
b. Providing any fixed building service in the building for the first time.
c. Increasing the capacity of any fixed building service (which does not include doing so on
account of renewable technology).
Consequential improvements should be carried out to ensure that the entire building complies
with Part L of the Building Regulations to the extent that they are technically, functionally and
economically feasible.
NOTE: If the building already complies with the current requirements of Part L of the Building
Regulations, consequential improvements are not required.
12.2 Where work other than the items listed in paragraph 12.1 is planned as part of the principal works, if
they improve the energy performance of the building, these are consequential improvements. Work
carried out to compensate for the poorer standard of an extension using the alternative approach
to demonstrating compliance described in paragraph 10.11 does not count as a consequential
improvement.
Consequential improvements which apply when extending
a building
NOTE: A new free-standing building constructed on an existing site is a new building, not an
extension.
12.3 When an existing building with a total useful floor area of over 1000m2 is being extended or the
habitable area is being increased, consequential improvements should be installed. The measures
listed in Appendix D, Table D1, may be considered technically, functionally and economically
feasible in normal circumstances.
12.4 For an extension or increase in habitable area, the value of the principal works is used to determine
the minimum value of the consequential improvement works. The value of the consequential
improvement works should not be less than 10% of the value of the principal works.
12.5 As part of the initial notice or deposit of plans, a chartered quantity surveyor or other suitably
qualified person should produce a signed report that establishes the value of the principal works
and the value of the consequential improvements using prices current at the date when the
building control body is informed of the proposals.
82
Approved Document L Volume 2, 2021 edition Building Regulations 2010
O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.