Appendix A: Key terms
NOTE: Except for the items marked * (which Building primary energy rate Expressed as kWh /
PE
are from the Building Regulations 2010), these (m2.year) and determined using the approved
definitions apply only to Approved Document L, methodology.
Volume 2: Buildings other than dwellings.
Centralised electrically heated A domestic hot
Air permeability The measure of airtightness of water system in which the water is supplied to
the building fabric. It is defined as the air leakage the draw-off points from a device in which water
rate per hour per m2 of envelope area at the test is heated by an electric element or elements
reference pressure differential of 50Pa. immersed in the stored water. The water heater
is situated centrally with a distribution system
• The limiting air permeability is the worst
to supply water to the draw-off points and has a
allowable air permeability.
capacity greater than 300 litres.
• The design air permeability is the target value
Centre pane U-value The U-value determined
set at the design stage.
in the central area of the glazing unit, making no
• The assessed air permeability is the value used allowance for edge spacers or the window frame.
in establishing the building emission rate and
*Change to energy status Defined in regulation
the building primary energy rate. The assessed
2(1) as any change which results in a building
air permeability is based on a measurement of
becoming a building to which the energy efficiency
the air permeability of the building concerned.
requirements of these Regulations apply, where
Airtightness The resistance of the building previously it was not.
envelope to infiltration when ventilators are
CHPQA quality index An indicator of the energy
closed. The greater the airtightness at a given
efficiency and environmental performance of a
pressure difference across the envelope, the lower
CHP scheme, certified by the Combined Heat and
the infiltration. Building automation and control
Power Quality Assurance scheme.
system.
Circuit-watt Refers to the power consumed in
Building automation and control system A system
lighting circuits by lamps and, where applicable,
comprising all products, software and engineering
their associated control gear (including
services that can support energy efficient,
transformers and drivers) and power factor
economical and safe operation of heating,
correction equipment.
ventilation and air conditioning systems through
automatic controls and by facilitating the manual Coefficient of performance (COP) A measure
management of those building systems. of the efficiency of a heat pump at specified
source and sink temperatures, measured using the
Building control body A local authority building
procedures in BS EN 14511-2.
control department or an approved inspector.
• Heating COP = heat output / power input
Building emission rate The building’s CO emission
2
rate expressed as kgCO /(m2.year). • % COP (COP � 100) is the heat generator
2
efficiency.
*Building envelope (in relation to a building)
Defined in regulation 35 as the walls, floor, roof,
windows, doors, roof windows and rooflights.
84
Approved Document L Volume 2, 2021 edition Building Regulations 2010