England · Statutory guidance
Conservation of fuel and power: Approved Document L, Volume 1 — Dwellings
Building regulation guidance on energy efficiency and the conservation of fuel and power.
- Edition
- 2021 edition incorporating 2023 amendments · Volume 1; later editions and transitions on source page
- Search coverage
- 104 of 104 PDF pages · 3 OCR pages
Energy & sustainability
Open original PDF at page 85 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
AA
e. the building is used as a public building, where Seasonal coefficient of performance (SCOP) A
previously it was not; measure of the efficiency of a heat pump over the
designated heating season, measured using the
f. the building is not a building described in
procedures in BS EN 14825.
classes 1 to 6 in Schedule 2, where previously it
was; Seasonal energy efficiency ratio (SEER) The total
amount of cooling energy provided by a single
g. the building, which contains at least one
cooling unit over a year, divided by the total energy
dwelling, contains a greater or lesser number of
input to that single cooling unit over the same year.
dwellings than it did previously;
Secondary circulation An assembly of water
h. the building contains a room for residential
fittings in which water circulates in supply pipes or
purposes, where previously it did not;
distributing pipes of hot water storage systems.
i. the building, which contains at least one room
Secondary heating A space heating appliance
for residential purposes, contains a greater
or system which operates separately from the
or lesser number of such rooms than it did
main heating system in the dwelling and does not
previously;
provide most of the heating in the dwelling – for
j. the building is used as a shop, where it example, a decorative fuel-effect fire in a room
previously was not; or which also contains radiators for a central heating
k. the building is a building described in regulation system.
7(4)(a), where previously it was not. SEDBUK (Seasonal Efficiency of Domestic Boilers
Primary circulation An assembly of water fittings in in the UK) The methodology for determining boiler
which water circulates between a heat source and efficiency defined in the Standard Assessment
a primary heat exchanger inside a hot water storage Procedure, Appendix D.
vessel, including any space heating system. Simple payback The amount of time it will take
Primary energy Energy, from renewable and non- to recover the initial investment through energy
renewable sources, that has not undergone any savings, calculated by dividing the marginal
conversion or transformation process. additional cost of implementing an energy
efficiency measure by the value of the annual
Renewable technology Technology that uses
energy savings achieved by that measure, taking no
renewable resources, which are naturally
account of VAT. The following guidance should be
replenished on a human timescale, to produce
used.
electricity. Resources include wind, wave, marine,
hydro, biomass and solar. • The marginal additional cost is the additional
cost (materials and labour) of incorporating, for
Rooflight A glazed unit installed out of plane with
example, additional insulation – not the whole
the surface of the roof on a kerb or upstand. Also
cost of the work.
sometimes referred to as a skylight.
• The cost of implementing the measure should
Roof window A window installed in the same
be based on prices current at the date when
orientation as, and in plane with, the surrounding roof.
the application is made to the building control
*Room for residential purposes Defined in body and be confirmed in a report signed by a
regulation 2(1) as a room, or a suite of rooms, suitably qualified person.
which is not a dwelling-house or a flat and which
• The annual energy savings should be estimated
is used by one or more persons to live and sleep
using the Standard Assessment Procedure.
and includes a room in a hostel, an hotel, a
boarding house, a hall of residence or a residential
home, but does not include a room in a hospital,
or other similar establishment, used for patient
accommodation.
BBuuiillddiinngg RReegguullaattiioonnss 22001100 AApppprroovveedd DDooccuummeenntt LL VVoolluummee 11,, 22002211 eeddiittiioonn 7755
O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.