England · Statutory guidance
Protection from falling, collision and impact: Approved Document K
Guidance covering stairs, ladders, ramps, guarding and protection from collision and impact.
- Edition
- 2013 edition; publisher updates on source page
- Search coverage
- 68 of 68 PDF pages · 1 OCR pages
Stairs & circulation
Open original PDF at page 12 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
this may be the case the Construction (Design and Management) Regulations 2007 provides detail
on procedures for safe use of temporary means of access, together with focus on effective planning
and management of risk.
0.7 Health and safety regulations such as the Workplace (Health, Safety and Welfare) Regulations 1992
may impose requirements on employers and those in control of premises used as workplaces in
relation to certain physical characteristics of the workplace. Where such regulations apply there
may be confusion as to whether the Building Regulations or health and safety requirements take
precedence, as both will apply. Where an inspector for the purposes of the Health and Safety at
Work, etc. Act 1974 has identified a contravention of such health and safety regulations they may
seek to serve an improvement notice to secure compliance. In such circumstances the inspector is
prevented by virtue of section 23(3) of the Health and Safety at Work, etc. Act 1974 from requiring
measures which are more onerous than necessary to comply with any requirements of the Building
Regulations, unless the specific requirement of health and safety regulations are themselves more
onerous. Where applicable the following cross-referencing should be made.
a. For building work relating to requirement K1 of the Building Regulations, regarding the design
of stairs, ladders and ramps, see regulation 17 of the Workplace (Health, Safety and Welfare)
Regulations 1992. Regulation 17 relates to permanent stairs, ladders and ramps on pedestrian
routes within the workplace premises, including those used to give access for maintenance to
parts of the workplace premises.
b. For building work relating to requirement K2 of the Building Regulations, regarding the avoidance
of risk from falling when working at height, see regulation 6 of the Work at Height Regulations
2005.
c. For building work relating to requirement K3 of the Building Regulations, regarding the design
of vehicle barriers and loading bays, see regulation 17 of the Workplace (Health, Safety and
Welfare) Regulations 1992.
d. For building work relating to requirement K4 of the Building Regulations, regarding the
prevention of personal injury, see regulation 14(1)(a) of the Workplace (Health, Safety and
Welfare) Regulations 1992.
e. For building work relating to requirement K5.1 of the Building Regulations, regarding the
requirements for projecting windows, skylights and ventilators, see regulation 15(2) of the
Workplace (Health, Safety and Welfare) Regulations 1992.
f. For building work relating to requirement K5.2 of the Building Regulations, regarding the
requirements for marking windows, transparent or translucent doors, gates and walls, see
regulation 14(1)(b) of the Workplace (Health, Safety and Welfare) Regulations 1992.
g. For building work relating to requirement K5.3 of the Building Regulations, regarding the
requirements for opening, closing or adjusting windows, skylights and ventilators, see regulation
15(1) of the Workplace (Health, Safety and Welfare) Regulations 1992.
h. For building work relating to requirement K5.4 of the Building Regulations, regarding the
requirements for cleaning windows and skylights, etc., see regulation 16 of the Workplace
(Health, Safety and Welfare) Regulations 1992.
i. For building work relating to requirement K6 of the Building Regulations, regarding the
requirements for doors and gates, see regulation 18 of the Workplace (Health, Safety and
Welfare) Regulations 1992.
2 Approved Documentttt KKKK,,,, 2222000011113333 eeeeddddiiiittttiiiioooonnnn Building Regulations 2010
OOO NNN LLL III NNN EEE VVV EEE RRR SSS III OOO NNN
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.