Protection from falling, collision and impact: Approved Document K

Guidance covering stairs, ladders, ramps, guarding and protection from collision and impact.

Stairs & circulation
Open original PDF at page 23

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

O N L I N E V E R S I O N K1 Stairs and ladders 1.30 The construction of an alternating tread stair should comply with all of the following. a. Comply with Diagram 1.10. b. Make alternating steps uniform with parallel nosings. c. Have slip-resistant surfaces on treads. d. Ensure that the tread sizes over the wider part of the step are in line with the dimensions in Table 1.1. e. Comply with paragraph 1.9b. f. Provide a minimum clear headroom of 2m. See paras 1.29 and 1.30 Handrail (both sides) Minimum going 220mm With this type of stair the going is measured between alternate nosings Maximum rise 220mm Diagram 1.10 Alternating tread stair Fixed ladders In dwellings 1.31 Do not use retractable ladders as means of escape. Refer to Approved Document B: Volume 1 – Dwellinghouses, and Volume 2 – Buildings other than dwellinghouses. 1.32 You may use a fixed ladder – with fixed handrails on both sides – only for access in a loft conversion that contains one habitable room, and only when there is not enough space without alteration to the existing space for a stair that satisfies the guidance for dwellings in paragraphs 1.2–1.24. For industrial buildings 1.33 Design and construct stairs, ladders and walkways, as appropriate, in accordance with BS 5395-3 or BS 4211. Building Regulations 2010 AAAApppppppprrrroooovvvveeeedddd DDDDooooccccuuuument K, 2013 edition 13 OOO NNN LLL III NNN EEE VVV EEE RRR SSS III OOO NNN

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.