England · Statutory guidance
Protection from falling, collision and impact: Approved Document K
Guidance covering stairs, ladders, ramps, guarding and protection from collision and impact.
- Edition
- 2013 edition; publisher updates on source page
- Search coverage
- 68 of 68 PDF pages · 1 OCR pages
Stairs & circulation
Open original PDF at page 35 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
K2
Protection from falling
See para 3.2 and Diagram 3.1 for location and dimensions
Stair
Edge of floor Edge of floor
Diagram 3.2 Typical locations for guarding
Guarding of areas used for maintenance
For all buildings
3.4 Where people will use the stairs or ladders to access areas for maintenance they should comply
with one of the following.
a. If access will be required frequently (e.g. a minimum of once per month): follow provisions such
as those suggested for dwellings in this Approved Document (see Diagram 3.1).
b. If access will be required less frequently than once a month: it may be appropriate to use
temporary guarding or warning notices. The Construction (Design and Management) Regulations
2007 and the Work at Height Regulations 2005 give provisions for such measures.
3.5 Use signs as specified in the Health and Safety (Safety Signs and Signals) Regulations 1996.
Building Regulations 2010 AAAApppppppprrrroooovvvveeeedddd DDDDooooccccuuuument K, 2013 edition 25