England · Statutory guidance
Protection from falling, collision and impact: Approved Document K
Guidance covering stairs, ladders, ramps, guarding and protection from collision and impact.
- Edition
- 2013 edition; publisher updates on source page
- Search coverage
- 68 of 68 PDF pages · 1 OCR pages
Stairs & circulation
Open original PDF at page 40 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
K4
Protection against impact with glazing
Requirement K4: Protection against impact
with glazing
This approved document deals with the following requirement from Part K of Schedule 1 to the
Building Regulations 2010.
Requirements
Requirement Limits on application
Protection against impact with glazing
K4.—Glazing, with which people are likely to come into
contact whilst moving in or about the building shall:
(a) if broken on impact, break in a way which is unlikely
to cause injury; or
(b) resist impact without breaking; or
(c) be shielded or protected from impact.
Performance
In the Secretary of State’s view, you can meet requirement K4 if you adopt, in critical locations, one
of the following approaches.
a. Measures to limit the risk of cutting and piercing injuries by the use of glazing that is reasonably
safe, such that, if breakage did occur, any particles would be relatively harmless.
b. Use of glazing sufficiently robust to ensure that the risk of breakage is low.
c. Steps are taken to limit the risk of contact with the glazing.
Impacts with glazing, particularly glazing in doors and door side panels, and at low level in walls
and partitions, can result in cutting and piercing injuries. For doors and door side panels, the risk is
greatest for glazing between floor and shoulder level when near to door handles and push plates,
especially when normal building movement causes doors to stick.
Hands, wrists and arms are particularly vulnerable. An initial impact at between waist and shoulder
levels can be followed by a fall through the glazing, resulting in additional injury to the face and
body.
In walls and partitions, away from doors, the risks relate predominantly to glazing at low level. At
that level, children are especially vulnerable.
30 Approved Documentttt KKKK,,,, 2222000011113333 eeeeddddiiiittttiiiioooonnnn Building Regulations 2010
OOO NNN LLL III NNN EEE VVV EEE RRR SSS III OOO NNN
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.