K5
Protection from collision with open windows etc.
.1
Requirement K5.1: Protection from collision
with open windows etc.
This approved document deals with the following requirement from Part K of Schedule 1 to the
Building Regulations 2010.
Requirements
Requirement Limits on application
Protection from collision with open windows etc.
K5.1—Provision shall be made to prevent people moving Requirement K5.1 does not apply to dwellings.
in or about the building from colliding with open
windows, skylights or ventilators.
Performance
In the Secretary of State’s view, you can meet requirement K5.1 if windows, skylights and ventilators
can be left open without danger of people colliding with them. You can achieve this by one of the
following methods.
a. Install windows, skylights and ventilators so that projecting parts cannot come into contact with
people moving in and around the building.
b. Install features which guide people moving in or around the building away from any open
window, skylight or ventilator.
In special cases, such as in spaces where access is required only for maintenance, greater care can
be expected from people and therefore a lower standard of provision may be acceptable.