K5
Manifestation of glazing
.2
See para 7.3
<400mm<400mm
1400mm to 1600mm
850mm to 1000mm
a. Glazing less b. Glazing with a rail c. A single pane d. Glazed doors with no frame,
than 400mm in between 850mm to glazed door with or narrow frames, but with a
width between 1000mm and 1400mm a substantial large handle or push plate
frames to 1600mm above frame on each single pane
the floor
Diagram 7.1 Examples of door-height glazing not warranting manifestation
See para 7.4
1600mm
1400mm
1000mm
850mm
Manifestation can take various forms, e.g.
broken or solid lines, patterns or company
logos
Diagram 7.2 Height of manifestation for glass doors and glazed screens
40 Approved Documentttt KKKK,,,, 2222000011113333 eeeeddddiiiittttiiiioooonnnn Building Regulations 2010