England · Statutory guidance
Structure: Approved Document A
Guidance on structural loading, foundations, walls, floors, roofs and disproportionate collapse.
- Edition
- 2004 edition incorporating 2010 and 2013 amendments
- Search coverage
- 54 of 54 PDF pages · 1 OCR pages
Structure
Open original PDF at page 47 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
REDUCING THE SEONSNITILVIITYN OEF T HVEE BURILSDINI GO TNO
A3
DISPROPORTIONATE COLLAPSE IN THE EVENT OF AN ACCIDENT
BS EN 1990:2002+A1:2005 with its UK National ‘Guidance on Robustness and Provision against
Annex provides guidance on accidental Accidental Actions’, dated July 1999.
design loading and accidental actions loading
‘Proposed Revised Guidance on meeting
combination for ‘key elements’ and expressions
Compliance with the requirements of Building
6.11a and 6.11b of that Standard are relevant.
Regulation Part A3’. Revision of the Allott and
Note: Annex A of BS EN 1991-1-7:2006 with Lomax proposals. Project Report No. 205966.
its UK National Annex provides corresponding
Both of the above documents are available on
guidance for ‘key elements’.
www.planningportal.gov.uk
Load-bearing construction
‘Practical Guide to Structural Robustness and
For the purposes of this Guidance the term ‘load- Disproportionate Collapse in Buildings’ dated
bearing wall construction’ includes masonry October 2010. Published by The Institution of
cross-wall construction and walls comprising Structural Engineers, London.
close centred timber or lightweight steel section
studs. Seismic design
Alternative approach 5.5 Seismic design is not usually required
for buildings classified by Table 11 as being
5.4 As an alternative to Table 11, for any in Consequence Classes 1, 2a and 2b. For
building which does not fall into the classes listed buildings classified as Consequence Class 3 the
under Table 11, or for which the consequences risk assessment should consider if there is any
of collapse may warrant particular examination need to carry out seismic design, although such
of the risks involved, performance may be a need is not an explicit requirement for these
demonstrated using the recommendations given buildings.
in the following Reports and Publication:
Diagram 24 Area at risk of collapse in the event of an accident
See para 5.1d
Area at risk of collapse
limited to 15% of the
floor area of that storey
or 100m2, whichever is
the lesser, and does not
extend further than the
immediate adjacent
storeys
Approved Document A Structure
O N L I N E V E R S I O N 45
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.