England · Statutory guidance
Structure: Approved Document A
Guidance on structural loading, foundations, walls, floors, roofs and disproportionate collapse.
- Edition
- 2004 edition incorporating 2010 and 2013 amendments
- Search coverage
- 54 of 54 PDF pages · 1 OCR pages
Structure
Open original PDF at page 53 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
MAIN CHANGES MADE BY THE MAIN CHANGES IN THE APPROVED DOCUMENTS
2013 AMENDMENTS 2004 EDITION The following documents have been published
to give practical guidance about how to meet the
The main changes are to:
The 2004 edition replaced the 1992 Edition (with Building Regulations. You can find the date of the
• References to British Standard design 1994 and 2000 amendments edition). The main edition approved by the Secretary of State at
standards changes were: www.planningportal.gov.uk.
• Guidance on disproportionate collapse • Guidance on the sizing of timber floors and Approved Document A
roofs for traditional house construction Structure
• Wind maps
removed, as the Timber Tables are now
Approved Document B: Volume 1
• Guidance on strip footings published by TRADA.
Fire safety – Dwellinghouses
• Materials and workmanship • Map of basic wind speeds revised.
Approved Document B: Volume 2
There have been no changes to Part A of • Stainless steel cavity wall ties specified for all Fire safety – Buildings other than dwellinghouses
Schedule 1 to the Building Regulations. houses regardless of their location.
Approved Document C
• Guidance on masonry walls to dwellings Site preparation and resistance to contaminants
MAIN CHANGES MADE BY THE
extended. and moisture
2010 AMENDMENTS
• Guidance on concrete foundations to houses Approved Document D
The 2010 amendments reflect the Building revised. Toxic substances
Regulations 2010 and Building (Approved • Guidance on the design and construction of Approved Document E
Inspectors etc) Regulations 2010. The changes domestic garages extensively updated. Resistance to the passage of sound
mainly reflect regulation number changes as
a result of re-ordering. There have been no • Disproportionate collapse: the Application Approved Document F
amendments to the substantive requirements in Limit to Requirement A3 (ie. the 5 storey limit) Ventilation
Part A of Schedule 1 to the Building Regulations. removed to bring all buildings under control of Approved Document G
Requirement A3.
Sanitation, hot water safety and water efficiency
Approved Document H
Drainage and waste disposal
Approved Document J
Combustion appliances and fuel storage systems
Approved Document K
Protection from falling, collision and impact
Approved Document L1A
Conservation of fuel and power in new dwellings
Approved Document L1B
Conservation of fuel and power in existing
dwellings
Approved Document L2A
Conservation of fuel and power in new buildings
other than dwellings
Approved Document L2B
Conservation of fuel and power in existing
buildings other than dwellings
Approved Document M
Access to and use of buildings
Approved Document P
Electrical Safety – Dwellings
Approved Document 7
Materials and workmanship
This printing incorporates editorial amendments
and corrections.
O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.