Ventilation: Approved Document F, Volume 2 — Buildings other than dwellings

Ventilation guidance for non-domestic buildings, including outdoor air supply, extract ventilation and commissioning.

Ventilation
Open original PDF at page 11

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

O N L I N E V E R S I O N Live/work units 0.11 A unit that contains both living accommodation and space for commercial purposes (e.g. for a workshop or office) should be treated as a dwelling if the commercial part can be reverted to domestic use. 0.12 The commercial part of the building can be reverted to domestic use if all of the following apply. a. There is direct access between the commercial space and the living accommodation. b. The commercial space and living accommodation are within the same thermal envelope. c. The living accommodation comprises a substantial proportion of the total area of the unit. What constitutes a ‘substantial proportion’ should be assessed on a case-by-case basis by the building control body. NOTE: A large non-domestic building that contains a small flat for a manager is not treated as a dwelling. A dwelling that contains a room used as an office or utility space is still treated as a dwelling. Mixed-use developments 0.13 When constructing a dwelling as part of a larger building that contains other types of accommodation, sometimes called a mixed-use development, refer to the two volumes of Approved Document F as follows. a. For guidance on each individual dwelling, use Approved Document F, Volume 1: Dwellings. b. For guidance on the non-dwelling parts of the building, such as shared communal rooms and commercial or retail space, use this approved document: Approved Document F, Volume 2: Buildings other than dwellings. Selected key interactions with other parts of the Building Regulations 0.14 The approved documents set out what, in ordinary circumstances, may be accepted as one way to comply with the Building Regulations. Those designing or undertaking building work remain responsible for assessing, on a case-by-case basis, whether specific circumstances require additional or alternative measures to comply with the regulatory requirements. There are interactions between many of the requirements of the Building Regulations. Guidance on some key interactions is given below. Interaction with Part B 0.15 The requirements of Part B apply if, for example, ducts pass through any of the following. a. A fire resisting structure. b. A fire compartment. c. A protected stairway. 0.16 This approved document gives guidance on window openings for ventilation. In addition, Approved Document B gives guidance on the size of escape windows. The larger of the window openings specified in Approved Document B or Approved Document F should be applied in all cases. 3 Building Regulations 2010 Approved Document F Volume 2, 2021 edition O N L I N E V E R S I O N

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.