Building regulation guidance on ventilation for dwellings and other buildings.

Ventilation
Open original PDF at page 31

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

O N L I N E V E R S I O N F1(1) Table 3.1 Energy efficiency measures Category of measure Roof insulation a. Renewing loft insulation, including effective edge sealing at junctions and penetrations Minor b. Loft conversions or works that include changing a cold loft (insulation at ceiling level) to Minor a warm loft (insulation at roof level) Wall insulation c. Installing cavity wall insulation to any external wall Minor d. Installing external or internal wall insulation to less than or equal to 50% of the external Minor wall area e. Installing external or internal wall insulation to more than 50% of the external wall area Major Replacement of windows and doors(1) f. Replacing less than or equal to 30% of the total existing windows or door units Minor g. Replacing more than 30% of the total existing windows or door units Major Draught-proofing (other than openings)(2) h. Replacing a loft hatch with a sealed/insulated unit Minor i. Sealing around structural or service penetrations through walls, floors or ceiling/roof Minor j. Sealing and/or insulating a suspended ground floor Major k. Removing chimney or providing another means of sealing over chimney, internally or Major externally NOTES: 1. If the energy efficiency works involve only replacing windows, then the guidance in paragraphs 3.14 to 3.16 may be followed as an alternative means of demonstrating compliance. 2. Draught-proofing measures might not, on their own, constitute building work. This work may be controllable under the Building Regulations if carried out as part of other building work. Number of minor measures 0 1 2 3 4 5 6 0 Category A 1 Number Category B of major 2 measures 3 Category C 4 Diagram 3.1 C hart for categorising impact on ventilation when carrying out works in existing dwellings 3.10 If the method in Diagram 3.1 results in the work being categorised as Category A, it is likely that the energy efficiency measures have not reduced the ventilation provision of the dwelling below the requirements of F1(1) so no further ventilation provision is necessary. 23 Building Regulations 2010 Approved Document F Volume 1, 2021 edition O N L I N E V E R S I O N

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.