CHAPTER 3: BUILDING BLOCKS TECHNICAL obstructions 24 inches (610 mm) minimum. The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm. Figure 304.3.2 T-Shaped Turning Space 304.4 Door Swing. Doors shall be permitted to swing into turning spaces. 305 Clear Floor or Ground Space 305.1 General. Clear floor or ground space shall comply with 305. 305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 305.3 Size. The clear floor or ground space shall be 30 inches (760 mm) minimum by 48 inches (1220 mm) minimum. D1e4p4artment of Justice 2010 Standards: Titles II and III - 107 Titles II and III - 2010 Standards - 78

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.