United States · ADA · Accessibility standard
2010 ADA Standards for Accessible Design
The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.
- Publisher
- U.S. Department of Justice
- Edition
- 2010 standards
- Search coverage
- 279 of 279 PDF pages · 2 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 113 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
CHAPTER 3: BUILDING BLOCKS TECHNICAL
305.7.1 Forward Approach. Alcoves shall be 36 inches (915 mm)wide minimum where the depth
exceeds 24 inches (610 mm).
Figure 305.7.1
Maneuvering Clearance in an Alcove, Forward Approach
305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth
exceeds 15 inches (380 mm).
Figure 305.7.2
Maneuvering Clearance in an Alcove, Parallel Approach
306 Knee and Toe Clearance
306.1 General. Where space beneath an element is included as part of clear floor or ground space or
turning space, the space shall comply with 306. Additional space shall not be prohibited beneath an
element but shall not be considered as part of the clear floor or ground space or turning space.
Advisory 306.1 General. Clearances are measured in relation to the usable clear floor
space, not necessarily to the vertical support for an element. When determining clearance
under an object for required turning or maneuvering space, care should be taken to ensure
the space is clear of any obstructions.
D1e4p6artment of Justice 2010 Standards: Titles II and III - 109
Titles II and III - 2010 Standards - 80
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.