Skip to content

United States · ADA · Accessibility standard

2010 ADA Standards for Accessible Design

The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 131

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL by reference, see “Referenced Standards” in Chapter 1). Low-energy and power-assisted doors shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see “Referenced Standards” in Chapter 1). 404.3.1 Clear Width. Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode. The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. 404.3.2 Maneuvering Clearance. Clearances at power-assisted doors and gates shall comply with 404.2.4. Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with 404.2.4. EXCEPTION: Where automatic doors and gates remain open in the power-off condition, compliance with 404.2.4 shall not be required. 404.3.3 Thresholds. Thresholds and changes in level at doorways shall comply with 404.2.5. 404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6. 404.3.5 Controls. Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing. 404.3.6 Break Out Opening. Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated in emergency mode. EXCEPTION: Where manual swinging doors and gates comply with 404.2 and serve the same means of egress compliance with 404.3.6 shall not be required. 404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route. 405 Ramps 405.1 General. Ramps on accessible routes shall comply with 405. EXCEPTION: In assembly areas, aisle ramps adjacent to seating and not serving elements required to be on an accessible route shall not be required to comply with 405. 405.2 Slope. Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space limitations. D1e6p4artment of Justice 2010 Standards: Titles II and III - 127

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.