CHAPTER 7: COMMUNICATION ELEMENTS AND FEATURES TECHNICAL EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters or symbols. Figure 703.3.2 Position of Braille 703.4 Installation Height and Location. Signs with tactile characters shall comply with 703.4. 703.4.1 Height Above Finish Floor or Ground. Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches (1525 mm) maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. EXCEPTION: Tactile characters for elevator car controls shall not be required to comply with 703.4.1. Figure 703.4.1 Height of Tactile Characters Above Finish Floor or Ground D2e2p6artment of Justice 2010 Standards: Titles II and III - 189 Titles II and III - 2010 Standards - 160