CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS TECHNICAL
806.2.5 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804.
806.2.6 Turning Space. Turning space complying with 304 shall be provided within the guest room.
806.3 Guest Rooms with Communication Features. Guest rooms required to provide communication
features shall comply with 806.3.
Advisory 806.3 Guest Rooms with Communication Features. In guest rooms required
to have accessible communication features, consider ensuring compatibility with adaptive
equipment used by people with hearing impairments. To ensure communication within the
facility, as well as on commercial lines, provide telephone interface jacks that are compatible
with both digital and analog signal use. If an audio headphone jack is provided on a speaker
phone, a cutoff switch can be included in the jack so that insertion of the jack cuts off the
speaker. If a telephone-like handset is used, the external speakers can be turned off when
the handset is removed from the cradle. For headset or external amplification system
compatibility, a standard subminiature jack installed in the telephone will provide the most
flexibility.
806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall
be provided.
806.3.2 Notification Devices. Visible notification devices shall be provided to alert room occupants
of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to
visible alarm signal appliances. Telephones shall have volume controls compatible with the
telephone system and shall comply with 704.3. Telephones shall be served by an electrical outlet
complying with 309 located within 48 inches (1220 mm) of the telephone to facilitate the use of a
TTY.
807 Holding Cells and Housing Cells
807.1 General. Holding cells and housing cells shall comply with 807.
807.2 Cells with Mobility Features. Cells required to provide mobility features shall comply with 807.2.
807.2.1 Turning Space. Turning space complying with 304 shall be provided within the cell.
807.2.2 Benches. Where benches are provided, at least one bench shall comply with 903.
807.2.3 Beds. Where beds are provided, clear floor space complying with 305 shall be provided on
at least one side of the bed. The clear floor space shall be positioned for parallel approach to the
side of the bed.
807.2.4 Toilet and Bathing Facilities. Toilet facilities or bathing facilities that are provided as part of
a cell shall comply with 603. Where provided, no fewer than one water closet, one lavatory, and one
bathtub or shower shall comply with the applicable requirements of 603 through 610.
D2e4p8artment of Justice 2010 Standards: Titles II and III - 211