United States · ADA · Accessibility standard
2010 ADA Standards for Accessible Design
The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.
- Publisher
- U.S. Department of Justice
- Edition
- 2010 standards
- Search coverage
- 279 of 279 PDF pages · 2 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 250 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
TECHNICAL CHAPTER 10: RECREATION FACILITIES
1009.3 Sloped Entries. Sloped entries shall comply with 1009.3.
Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be
appropriate for submerging in water. Some may have batteries, motors, and electrical
systems that when submerged in water may cause damage to the personal mobility device
or wheelchair or may contaminate the pool water. Providing an aquatic wheelchair made of
non-corrosive materials and designed for access into the water will protect the water from
contamination and avoid damage to personal wheelchairs or other mobility aids.
1009.3.1 Sloped Entries. Sloped entries shall comply with Chapter 4 except as modified in
1109.3.1 through 1109.3.3.
EXCEPTION: Where sloped entries are provided, the surfaces shall not be required to be slip
resistant.
1009.3.2 Submerged Depth. Sloped entries shall extend to a depth of 24 inches (610 mm)
minimum and 30 inches (760 mm) maximum below the stationary water level. Where landings are
required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches
(760 mm) maximum below the stationary water level.
EXCEPTION: In wading pools, the sloped entry and landings, if provided, shall extend to the
deepest part of the wading pool.
Figure 1009.3.2
Sloped Entry Submerged Depth
1009.3.3 Handrails. At least two handrails complying with 505 shall be provided on the sloped entry.
The clear width between required handrails shall be 33 inches (840 mm) minimum and 38 inches
(965 mm) maximum.
EXCEPTIONS: 1. Handrail extensions specified by 505.10.1 shall not be required at the bottom
landing serving a sloped entry.
2. Where a sloped entry is provided for wave action pools, leisure rivers, sand bottom pools, and
other pools where user access is limited to one area, the handrails shall not be required to
comply with the clear width requirements of 1009.3.3.
3. Sloped entries in wading pools shall not be required to provide handrails complying with
1009.3.3. If provided, handrails on sloped entries in wading pools shall not be required to comply
with 505.
246 - 2010 Standards: Titles II and III Department of Jus2ti8c3e
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.