United States · ADA · Accessibility standard
2010 ADA Standards for Accessible Design
The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.
- Publisher
- U.S. Department of Justice
- Edition
- 2010 standards
- Search coverage
- 279 of 279 PDF pages · 2 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 256 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
TECHNICAL CHAPTER 10: RECREATION FACILITIES
1009.6 Pool Stairs. Pool stairs shall comply with 1009.6.
1009.6.1 Pool Stairs. Pool stairs shall comply with 504.
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high
minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform.
1009.6.2 Handrails. The width between handrails shall be 20 inches (510 mm) minimum and 24
inches (610 mm) maximum. Handrail extensions required by 505.10.3 shall not be required on pool
stairs.
1010 Shooting Facilities with Firing Positions
1010.1 Turning Space. A circular turning space 60 inches (1525 mm) diameter minimum with slopes
not steeper than 1:48 shall be provided at shooting facilities with firing positions.
252 - 2010 Standards: Titles II and III Department of Jus2ti8c9e
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.