ADA CHAPTER 1: APPLICATION AND ADMINISTRATION AMERICANS WITH DISABILITIES ACT: SCOPING
104.1.1 Construction and Manufacturing Tolerances. All dimensions are subject to conventional
industry tolerances except where the requirement is stated as a range with specific minimum and
maximum end points.
Advisory 104.1.1 Construction and Manufacturing Tolerances. Conventional industry
tolerances recognized by this provision include those for field conditions and those that may
be a necessary consequence of a particular manufacturing process. Recognized tolerances
are not intended to apply to design work.
It is good practice when specifying dimensions to avoid specifying a tolerance where
dimensions are absolute. For example, if this document requires “1½ inches,” avoid
specifying “1½ inches plus or minus X inches.”
Where the requirement states a specified range, such as in Section 609.4 where grab bars
must be installed between 33 inches and 36 inches above the floor, the range provides an
adequate tolerance and therefore no tolerance outside of the range at either end point is
permitted.
Where a requirement is a minimum or a maximum dimension that does not have two
specific minimum and maximum end points, tolerances may apply. Where an element is to
be installed at the minimum or maximum permitted dimension, such as “15 inches minimum”
or “5 pounds maximum”, it would not be good practice to specify “5 pounds (plus X pounds)
or 15 inches (minus X inches).” Rather, it would be good practice to specify a dimension
less than the required maximum (or more than the required minimum) by the amount of the
expected field or manufacturing tolerance and not to state any tolerance in conjunction with
the specified dimension.
Specifying dimensions in design in the manner described above will better ensure that
facilities and elements accomplish the level of accessibility intended by these requirements.
It will also more often produce an end result of strict and literal compliance with the stated
requirements and eliminate enforcement difficulties and issues that might otherwise arise.
Information on specific tolerances may be available from industry or trade organizations,
code groups and building officials, and published references.
104.2 Calculation of Percentages. Where the required number of elements or facilities to be provided
is determined by calculations of ratios or percentages and remainders or fractions result, the next
greater whole number of such elements or facilities shall be provided. Where the determination of the
required size or dimension of an element or facility involves ratios or percentages, rounding down for
values less than one half shall be permitted.
104.3 Figures. Unless specifically stated otherwise, figures are provided for informational purposes
only.
368 - 2010 Standards: Titles II and III Department of Justice
Titles II and III - 2010 Standards - 8
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.