AMERICANS WITH DISABILITIES ACT: SCOPING ADA CHAPTER 2: SCOPING REQUIREMENTS
Advisory 206.2.7 Press Boxes Exception 2. Where a facility contains multiple assembly
areas, the aggregate area of the press boxes in each assembly area is to be calculated
separately. For example, if a university has a soccer stadium with three press boxes
elevated 12 feet (3660 mm) or more above grade and each press box is 150 square feet (14
m2), then the aggregate area of the soccer stadium press boxes is less than 500 square feet
(46 m2) and Exception 2 applies to the soccer stadium. If that same university also has a
football stadium with two press boxes elevated 12 feet (3660 mm) or more above grade and
one press box is 250 square feet (23 m2), and the second is 275 square feet (26 m2), then
the aggregate area of the football stadium press boxes is more than 500 square feet (46 m2)
and Exception 2 does not apply to the football stadium.
206.2.8 Employee Work Areas. Common use circulation paths within employee work areas shall
comply with 402.
EXCEPTIONS: 1. Common use circulation paths located within employee work areas that are
less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters,
casework, or furnishings shall not be required to comply with 402.
2. Common use circulation paths located within employee work areas that are an integral
component of work area equipment shall not be required to comply with 402.
3. Common use circulation paths located within exterior employee work areas that are fully
exposed to the weather shall not be required to comply with 402.
Advisory 206.2.8 Employee Work Areas Exception 1. Modular furniture that is not
permanently installed is not directly subject to these requirements. The Department of
Justice ADA regulations provide additional guidance regarding the relationship between
these requirements and elements that are not part of the built environment. Additionally, the
Equal Employment Opportunity Commission (EEOC) implements title I of the ADA which
requires non-discrimination in the workplace. EEOC can provide guidance regarding
employers’ obligations to provide reasonable accommodations for employees with
disabilities.
Advisory 206.2.8 Employee Work Areas Exception 2. Large pieces of equipment, such
as electric turbines or water pumping apparatus, may have stairs and elevated walkways
used for overseeing or monitoring purposes which are physically part of the turbine or pump.
However, passenger elevators used for vertical transportation between stories are not
considered “work area equipment” as defined in Section 106.5.
206.2.9 Amusement Rides. Amusement rides required to comply with 234 shall provide accessible
routes in accordance with 206.2.9. Accessible routes serving amusement rides shall comply with
Chapter 4 except as modified by 1002.2.
206.2.9.1 Load and Unload Areas. Load and unload areas shall be on an accessible route.
Where load and unload areas have more than one loading or unloading position, at least one
loading and unloading position shall be on an accessible route.
Department of Justice 2010 Standards: Titles II and III - 2579
Titles II and III - 2010 Standards - 29