Skip to content

United States · ADA · Accessibility standard

2010 ADA Standards for Accessible Design

The Department of Justice’s scoping and technical accessibility requirements for facilities covered by the ADA.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 72

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

ADA CHAPTER 2: SCOPING REQUIREMENTS AMERICANS WITH DISABILITIES ACT: SCOPING 209.2.3 On-Street Bus Stops. On-street bus stops shall comply with 810.2 to the maximum extent practicable. 209.3 Medical Care and Long-Term Care Facilities. At least one passenger loading zone complying with 503 shall be provided at an accessible entrance to licensed medical care and licensed long-term care facilities where the period of stay exceeds twenty-four hours. 209.4 Valet Parking. Parking facilities that provide valet parking services shall provide at least one passenger loading zone complying with 503. 209.5 Mechanical Access Parking Garages. Mechanical access parking garages shall provide at least one passenger loading zone complying with 503 at vehicle drop-off and vehicle pick-up areas. 210 Stairways 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply with 504. EXCEPTIONS: 1. In detention and correctional facilities, stairs that are not located in public use areas shall not be required to comply with 504. 2. In alterations, stairs between levels that are connected by an accessible route shall not be required to comply with 504, except that handrails complying with 505 shall be provided when the stairs are altered. 3. In assembly areas, aisle stairs shall not be required to comply with 504. 4. Stairs that connect play components shall not be required to comply with 504. Advisory 210.1 General. Although these requirements do not mandate handrails on stairs that are not part of a means of egress, State or local building codes may require handrails or guards. 211 Drinking Fountains 211.1 General. Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with 211. EXCEPTION: In detention or correctional facilities, drinking fountains only serving holding or housing cells not required to comply with 232 shall not be required to comply with 211. 211.2 Minimum Number. No fewer than two drinking fountains shall be provided. One drinking fountain shall comply with 602.1 through 602.6 and one drinking fountain shall comply with 602.7. EXCEPTION: Where a single drinking fountain complies with 602.1 through 602.6 and 602.7, it shall be permitted to be substituted for two separate drinking fountains. 211.3 More Than Minimum Number. Where more than the minimum number of drinking fountains specified in 211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with 602.1 through 602.6, and 50 percent of the total number of drinking fountains provided shall comply with 602.7. 6386 - 2010 Standards: Titles II and III Department of Justice Titles II and III - 2010 Standards - 38

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.