ADA CHAPTER 2: SCOPING REQUIREMENTS AMERICANS WITH DISABILITIES ACT: SCOPING
rooms and spaces, the pictograms shall comply with 703.6 and shall have text descriptors complying
with 703.2 and 703.5.
EXCEPTION: Exterior signs that are not located at the door to the space they serve shall not be
required to comply with 703.2.
Advisory 216.2 Designations. Section 216.2 applies to signs that provide designations,
labels, or names for interior rooms or spaces where the sign is not likely to change over
time. Examples include interior signs labeling restrooms, room and floor numbers or letters,
and room names. Tactile text descriptors are required for pictograms that are provided to
label or identify a permanent room or space. Pictograms that provide information about a
room or space, such as “no smoking,” occupant logos, and the International Symbol of
Accessibility, are not required to have text descriptors.
216.3 Directional and Informational Signs. Signs that provide direction to or information about interior
spaces and facilities of the site shall comply with 703.5.
Advisory 216.3 Directional and Informational Signs. Information about interior spaces
and facilities includes rules of conduct, occupant load, and similar signs. Signs providing
direction to rooms or spaces include those that identify egress routes.
216.4 Means of Egress. Signs for means of egress shall comply with 216.4.
216.4.1 Exit Doors. Doors at exit passageways, exit discharge, and exit stairways shall be identified
by tactile signs complying with 703.1, 703.2, and 703.5.
Advisory 216.4.1 Exit Doors. An exit passageway is a horizontal exit component that is
separated from the interior spaces of the building by fire-resistance-rated construction and
that leads to the exit discharge or public way. The exit discharge is that portion of an egress
system between the termination of an exit and a public way.
216.4.2 Areas of Refuge. Signs required by section 1003.2.13.5.4 of the International Building
Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition)
(incorporated by reference, see “Referenced Standards” in Chapter 1) to provide instructions in
areas of refuge shall comply with 703.5.
216.4.3 Directional Signs. Signs required by section 1003.2.13.6 of the International Building Code
(2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by
reference, see “Referenced Standards” in Chapter 1) to provide directions to accessible means of
egress shall comply with 703.5.
216.5 Parking. Parking spaces complying with 502 shall be identified by signs complying with 502.6.
EXCEPTIONS: 1. Where a total of four or fewer parking spaces, including accessible parking
spaces, are provided on a site, identification of accessible parking spaces shall not be required.
2. In residential facilities, where parking spaces are assigned to specific residential dwelling units,
identification of accessible parking spaces shall not be required.