Com par ison of Single-User Toilet Room L ayouts 1991 Standards and 2010 Standards Plan-3: Meets Both 1991 Standards and 2010 Standards 7’-0” x 5’-9” • 40.25 Square Feet This plan shows an example of a single-user toilet room that meets the minimum requirements of both the 1991 Standards and 2010 Standards. A T-shaped turning space has been used (see Fig. 3(a) of the 1991 Standards and Figure 304.3.2 of the 2010 Standards) to maintain a compact room size. An out- swinging door also minimizes the overall layout depth and cannot swing over the required clear floor space or clearance at any accessible plumbing fixture. This layout is eleven percent (11%) larger than the Plan-1A: 1991 Standards Minimum with Out-Swinging Door example shown at the beginning of these plan comparisons. DDeeppaarrttmmeenntt ooff JJuussttiiccee Department of Justice Guidance on the 2010 Standards: Titles II and III - 101

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.