Plan 3B: 12-Foot Wide Accessible Guest Room
This drawing shows an accessible 12-foot wide guest room with features that comply with the 2010 Standards.
Features include a standard roll-in shower with a seat, comparable vanity, wardrobe, and door connecting to
adjacent guest room. Furnishings include two beds.
12’-0”
7’-0” 2’-10”
door
DDeeppaarrttmmeenntt ooff JJuussttiiccee Department of Justice Guidance on the 2010 Standards: Titles II and III - 133
”11-’8
”7-’41
The following accessible features are provided in the
bathroom:
• Comparable vanity counter top space (section
806);
• Standard roll-in type shower with folding seat
(section 608.2.2);
• Recessed lavatory with vanity counter top permits
shorter rear grab bar at water closet (section
604.5.2);
• Clear floor space adjacent to shower min. 30
inches wide by 60 inches long (section 608.2.2);
• Circular turning space in room (section 603.2.1);
• Required clear floor spaces at fixtures and turning
space overlap (section 603.2.2);
• Turning space includes knee and toe clearance at
lavatory (section 304.3);
• Water closet clearance is 60 inches at back wall
and 56 inches deep (section 604.3);
• Centerline of the water closet at 16-18 inches from
side wall (section 604.2); and
• No other fixtures or obstructions located within
required water closet clearance (section 604.3).
The following accessible features are provided in the
living area:
• T-shaped turning space (section 304.3.2);
• Accessible route (section 402);
• Clear floor space between beds (section 806.2.3);
• Maneuvering clearances at all doors (section
404.2);
• Accessible operable window (section 309); and
• Accessible controls for the heat and air
conditioning (section 309).