United States · ADA · Guidance
Guidance on the 2010 ADA Standards for Accessible Design
The Department of Justice’s explanation of changes to the ADA design standards, with section-by-section analysis and responses to public comments.
- Publisher
- U.S. Department of Justice
- Edition
- September 2010 guidance
- Search coverage
- 168 of 170 PDF pages · 4 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 145 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
Analysis and Com menta ry on the 201 0 A DAStandards
Commenters stated that basing accessible of any sales and service counter to be the
seating on seating spaces and standing same as the level of service provided at the
spaces potentially represents a significant inaccessible portions of the counter.
increase in scoping, particularly given the
ambiguity in what represents a “standing The 2010 Standards specify different lengths
space” and urged a return to the 1991 for the accessible portion of sales and service
Standard of requiring accessible seating counters based on the type of approach
based on fixed dining tables. The scoping provided. Where a forward approach is
change merely takes into account that provided, the accessible portion of the
tables may vary in size so that basing counter must be at least 30 inches long and
the calculation on the number of tables no higher than 36 inches, and knee and toe
rather than on the number of individuals space must be provided under the counter.
that may be accommodated by the tables The requirement that knee and toe space
could unnecessarily restrict opportunities be provided where only clear floor space for
for persons with disabilities. The revised a forward approach to a sales and service
scoping permits greater flexibility by allowing counter is provided is not a new requirement.
designers to disperse accessible seating It is a clarification of the ongoing requirement
and standing spaces throughout the dining that part of the sales and service counter be
area. Human factors data, which is readily accessible. This requirement applies to the
available to designers, provides information entire accessible part of sales and service
about the amount of space required for both counters and requires that the accessible
eating and drinking while seated or standing. clear floor or ground space adjacent to those
counters be kept clear of merchandise,
227 and 904 Sales and Service equipment, and other items so that the
accessible part of the counter is readily
Check-Out Aisles and Sales and Service accessible to and usable by individuals
Counters. The 1991 Standards, at section with disabilities. The accessible part of the
7.2, and the 2010 Standards, at section counter must also be staffed and provide an
904.4, contain technical requirements equivalent level of service as that provided to
for sales and service counters. The 1991 all customers.
Standards generally require sales and
service counters to provide an accessible Where clear floor space for a parallel
portion at least 36 inches long and no approach is provided, the accessible portion
higher than 36 inches above the finish of the counter must be at least 36 inches
floor. The nondiscrimination requirements long and no higher than 36 inches above the
of the ADA regulations require the level of finish floor. A clear floor or ground space that
service provided at the accessible portion is at least 48 inches long x 30 inches wide
Department of Justice Guidance on the 2010 Standards: Titles II and III - 141
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.