United States · ADA · Illustrated standards guidance
Bathing rooms: showers, tubs and transfer spaces
Accessible shower and bathtub layouts, transfer clearances, seats, grab bars and reachable controls.
- Publisher
- U.S. Access Board
- Edition
- Access Board guide to the 2010 ADA standards
- Search coverage
- 42 of 42 PDF pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 36 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
Chapter 6: Plumbing Elements and Facilities Bathing Rooms
At least one compliant
lavatory (not located in a
toilet compartment) and Dispensers, receptacles,
at least one compliant and other operable parts
mirror, where provided must comply where
(§213.3.4 and §213.3.5) provided (§205)
Where coat hooks
or shelves are
provided, at least
one of each
type must serve
the accessible
shower or bathtub
Turning Space (§213.3.7)
(§603.2.1)
At least one
compliant shower or
At least one compliant
bathtub (§213.3.6)
urinal where more than
one urinal is provided
(§213.3.3)
At least one wheelchair accessible
toilet compartment (§213.3.1),
including door maneuvering At least one ambulatory accessible toilet
clearance at the compartment door compartment in bathing rooms with at least 6 toilet
compartments or where the combined total of
toilets and urinals is at least 6 fixtures (§213.3.1)
36
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.