Chapter 4: Accessible Routes Entrances, Doors, and Gates
Components of Accessible Entrances
Communication Systems (§230) Designation (§216.6)
Two-way communication systems, where International Symbol of Accessibility
provided, must be equipped with visual and label (not required if all public
a udible signals and compliant as operable parts entrances are accessible)
Doors and Doorways
(§206.5.1)
At least one compliant
door or doorway
Accessible Route (§206.3) Security Barriers (§206.8)
Accessible route to entrance from site Bollards and other security
arrival points and located in the same barriers cannot obstruct
area as general circulation paths accessible routes
Directional Signs at Inaccessible Entrances (§216.6)
Signs indicating the location of the nearest accessible entrances are required at
each inaccessible public entrance. These signs must include the International
Symbol of Accessibility and note direction. Additional content or text is not
specified, but can be helpful. It is advisable to locate signs in a manner that
minimizes back-tracking.