Operable parts: reach ranges and controls

Forward and side reach guidance for accessible controls, switches and other operable parts, including obstructed reaches.

AccessibilityAnthropometry & ergonomics
Open original PDF at page 5

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

Chapter 3: Building Blocks Operable Parts Forward Reach [§308.2] The range for unobstructed reaches (15” – 48”) applies only to those portions of elements that are operable. Non-operable portions can be located outside the range. 48” max 15” min Obstructed High Reach The maximum reach of 48” is reduced to 44” when the depth of reach over an obstruction exceeds 20.” Knee and toe space must extend the full depth of reach. 20” max >20 – 25” max 48” 44” max max 5