England · Statutory guidance
Access to and use of buildings: Approved Document M
Accessibility guidance for dwellings and buildings other than dwellings. The linked PDF is Volume 2.
- Edition
- PDF: Volume 2, 2015 edition incorporating 2020 and 2024 amendments
- Search coverage
- 74 of 74 PDF pages · 1 OCR pages
AccessibilityAnthropometry & ergonomics
Open original PDF at page 23 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
M1/M2
ACCESS TO BUILDINGS OTHER THAN DWELLINGS
Diagram 4 Stepped access – key dimensions and use of hazard warning surface
d. where there is side access onto an g. there are no single steps;
intermediate landing, a ‘corduroy’
h. the rise of a flight between landings
hazard warning surface 400mm deep
contains no more than 12 risers for a
is provided either on the intermediate
going of less than 350mm and no more
landing 400mm from both upper and
than 18 risers for a going of 350mm or
lower flights, if there is sufficient space
greater (see Diagram 5);
to accommodate the surface outside
the line of the side access, or within the i. all nosings are made apparent by
side access 400mm from the intermediate means of a permanently contrasting
landing if there is a continuous handrail material 55mm wide on both the tread
opposite the side access; and the riser;
e. no doors swing across landings; j. the projection of a step nosing over the
tread below is avoided but, if necessary,
f. it has flights whose surface width
not more than 25mm (see Diagram 6);
between enclosing walls, strings or
upstands is not less than 1.2m;
Approved Document M Volume 2 Access to and use of buildings other than dwellings
O N L I N E V E R S I O N 21
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.