M1/M2
Section 2: Access into buildings other
than dwellings
OBJECTIVES immediate environment, e.g. by lighting
and/or visual contrast;
2.1 The aim for all new buildings is for
the principal entrance or entrances and c. any structural supports at the entrance
any main staff entrance, and any lobbies, do not present a hazard for visually
to be accessible. impaired people;
2.2 Where it is not possible, e.g. in an d. there is a level landing at least 1500 x
existing building, for the principal or main 1500mm, clear of any door swings,
staff entrance or entrances to be accessible, immediately in front of the entrance and
an alternative accessible entrance should of a material that does not impede the
be provided. movement of wheelchairs;
2.3 It is important to reduce the risks to e. the threshold is level or, if a raised
people when entering the building. threshold is unavoidable, it has a total
height of not more than 15mm, a
Accessible entrances
minimum number of upstands and
slopes, with any upstands higher than
Design considerations
5mm chamfered or rounded;
2.4 Steeply sloping or restricted sites
f. any door entry systems are accessible
sometimes make it impossible for the
to deaf and hard of hearing people, and
principal or main staff entrance to be
people who cannot speak;
accessible, in which case an alternative
accessible entrance may be necessary. g. weather protection is provided at
manual non-powered entrance doors;
2.5 Accessible entrances should be
clearly sign-posted and easily recognisable. h. internal floor surfaces adjacent to the
Any structural elements, for example threshold are of materials that do not
supports for a canopy, are useful in impede the movement of wheelchairs,
identifying the entrance, but should not e.g. not coir matting, and changes in
present a hazard. floor materials do not create a potential
trip hazard;
2.6 The route from the exterior across
the threshold should provide weather i. where mat wells are provided, the
protection, and not present a barrier for surface of the mat is level with the
wheelchair users or a trip hazard for other surface of the adjacent floor finish;
people. A level threshold is preferred,
j. where provided as an alternative
especially for doors in frequent use.
accessible entrance, an accessible
Note: Guidance on sign-posting is given in internal route is provided to the spaces
BS 8300, Inclusive mobility and the Sign served by the principal or main staff
design guide. entrances.
Provisions Doors to accessible entrances
2.7 Accessible entrances will satisfy
Design considerations
Requirement M1 or M2 if:
2.8 Doors to the principal, or alternative
a. they are clearly sign-posted, incorporating
accessible, entrance should be accessible
the International Symbol of Access,
to all, particularly wheelchair users and
from the edge of the site and from the
people with limited physical dexterity.
principal entrance (if this is not accessible);
Entrance doors may be manually operated
b. they are easily identified among the without powered assistance, or power
other elements of the building and the operated under manual or automatic
Access to and use of buildings other than dwellings Approved Document M Volume 2
24 O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.