England · Statutory guidance
Conservation of fuel and power: Approved Document L, Volume 2 — Buildings other than dwellings
Energy performance guidance for non-domestic buildings, covering fabric, services, controls and commissioning.
- Edition
- 2021 edition incorporating 2023 amendments · Volume 2; later editions and transitions on source page
- Search coverage
- 116 of 116 PDF pages · 2 OCR pages
Energy & sustainability
Open original PDF at page 53 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N L1(b), L2
b. BS EN 13842.
The calculation of the thermal efficiency (net calorific value) should both:
a. exclude fans
b. take account of the radiant heater and associated flue pipe/tailpipe within the building
envelope.
Table 6.4 M inimum performance standards for radiant heaters
Appliance type Heat generator efficiency (net calorific value)
Thermal Radiant
Luminous radiant heater – unflued 86% 55%
Non-luminous radiant heater – unflued 86% 55%
Non-luminous radiant heater – flued 86% 55%
Multi-burner radiant heater 91% n/a
Electric space heating systems
NOTE: Electric resistance heating is assumed to be 100% efficient, therefore no minimum efficiency
is set for these types of system.
NOTE: This section of the guidance does not cover either of the following.
a. Electric heat pumps (guidance is provided in paragraphs 6.44 to 6.46).
b. Portable electric heating devices.
6.13 Electric space heating systems should meet the guidance in paragraphs 6.14 to 6.19, in addition to
the general requirements for heating systems in Section 5.
6.14 Electric boiler systems should comply with all of the following.
a. Systems should both:
i. have flow temperature control
ii. be capable of modulating the power input to the primary water depending on space
heating conditions.
b. Timing and temperature demand control should be provided.
c. If the building has a floor area greater than 150m2, heating should be split into different heating
zones and each zone should have separate controls for timing and temperature demand.
6.15 Electric warm air systems should comply with both of the following.
a. Have timing and temperature demand control provided.
b. If the building has a floor area greater than 150m2, heating should be split into different heating
zones and each zone should have separate controls for timing and temperature demand.
6.16 Electric radiant heaters should have automatic zone or occupancy control through presence
detection.
6.17 Electric panel or skirting heaters should have controls for timing and temperature demand.
6.18 The input charge for electric storage heaters should be adjusted automatically, based on the
internal air temperature. Manual control of heat release from the appliance should be possible.
43
Building Regulations 2010 Approved Document L Volume 2, 2021 edition
O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.