R6, R22 O N L I N E V E R S I O N For example, if external render is being removed from the outer side of a wall, the area of the thermal element is the area of the elevation in which that wall sits. Area of the thermal element being renovated Total area of the thermal element Diagram 11.1 Renovation of a thermal element from the outside For example, if plaster is being removed from the inner side of a wall, the area of the thermal element is the area of external wall as viewed from inside the room. Area of the thermal element being renovated Total area of the thermal element Diagram 11.2 Renovation of a thermal element from the inside 78 Approved Document L Volume 2, 2021 edition Building Regulations 2010 O N L I N E V E R S I O N