England · Statutory guidance
Conservation of fuel and power: Approved Document L, Volume 2 — Buildings other than dwellings
Energy performance guidance for non-domestic buildings, covering fabric, services, controls and commissioning.
- Edition
- 2021 edition incorporating 2023 amendments · Volume 2; later editions and transitions on source page
- Search coverage
- 116 of 116 PDF pages · 2 OCR pages
Energy & sustainability
Open original PDF at page 97 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N AA
c. any combination of systems of the kinds High-usage entrance door A door to an entrance
referred to in paragraph (a) or (b). primarily for people, through which many
people are expected to move. Robustness and/
Fixed external lighting Lighting fixed to an external
or powered operation are the main performance
surface of the building and supplied from the
requirements. A high-usage entrance door will have
occupier’s electrical system. It excludes lighting
automatic closers and, except where operational
in common areas of blocks of flats and in other
requirements preclude it, be protected by a lobby.
communal accessways.
Indirect-fired circulator A domestic hot water system
g-value A total solar energy transmittance.
in which the water is supplied to the draw-off points
Hard water Water which has a high mineral from a device in which water is heated by an element
content. For the purposes of this approved through which the heating medium is circulated so as
document, hard water is water that has a total not to mix with the hot water supply. In practice, the
water hardness of greater than 200ppm of CaCO . heat source is likely to be a boiler dedicated to the
3
supply of domestic hot water.
Heat generator seasonal efficiency The estimated
seasonal heat output from the heat generator
Installed capacity of a fixed building service per
divided by the energy input. unit area The design output of the distribution
system output devices (the terminal units) serving
Heating appliance or heat generator The part of
a heating system that generates useful heat using
the space in question, divided by the total useful
one or more of the following processes.
floor area of that space.
• The combustion of fuels in, for example, a Instantaneous electrically heated A domestic hot
water system in which the water is supplied to the
boiler.
draw-off points from a device in which cold water
• The Joule effect, taking place in the heating
is heated by an electric element or elements as it
elements of an electric resistance heating
flows through the water heater. The water heater
system.
is close to the draw-off points. The unit has no
• Capturing heat from ambient air, ventilation storage volume, as water is instantaneously heated
exhaust air, or a water or ground heat source as it flows through the device.
using a heat pump.
Light source lumens The sum of the average initial
Heating zone A conditioned area of a building (100 hour) lumen output of all the light sources
which is on a single floor and has the same in a luminaire. Does not include any losses or
thermal characteristics and temperature control inefficiencies of the luminaire.
requirements throughout.
Lighting Energy Numeric Indicator (LENI) A
High excitation purity light sources Colour- measure of the performance of lighting in terms
tuneable light sources that can be set to at least of energy per square metre per year (kWh/m2 per
the colours listed in Table A1 and which have for year). See Appendix B.
each of these colours, measured at the dominant
Local electrically heated A domestic hot water
wavelength, the minimum excitation purity shown.
system in which the water is supplied to the draw-
Intended for use in applications requiring high-
off points from a device in which water is heated
quality coloured light.
by an electric element or elements immersed in
the stored water. The water heater is near the
Table A1 H igh excitation purity light sources draw-off points and has a storage capacity of
between 100 and 300 litres.
Colour Dominant Minimum excitation
wavelength (nm) of purity (%)
Blue 440–490 90
Green 520–570 65
Red 610–670 95
8877
BBuuiillddiinngg RReegguullaattiioonnss 22001100 AApppprroovveedd DDooccuummeenntt LL VVoolluummee 22,, 22002211 eeddiittiioonn
O N L I N E V E R S I O N
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.