England · Statutory guidance
Protection from falling, collision and impact: Approved Document K
Guidance covering stairs, ladders, ramps, guarding and protection from collision and impact.
- Edition
- 2013 edition; publisher updates on source page
- Search coverage
- 68 of 68 PDF pages · 1 OCR pages
Stairs & circulation
Open original PDF at page 19 Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.
O N L I N E V E R S I O N
K1
Stairs and ladders
If more than 2m wide
See para 1.15
the flight should be divided
Divisions of flights should not be more than 2m wide,
measured between the inside edges of handrails
Diagram 1.5 Dividing flights
Length of flights of stairs
For all buildings
1.17 If stairs have more than 36 risers in consecutive flights, make a minimum of one change of direction
between flights, as shown in Diagram 1.6.
See paras 1.17 and 1.20
At least
stair width
Flight
Flight
Stair
Landing
width
Angle at
least 30˚
Diagram 1.6 Change of direction in flights
Building Regulations 2010 AAAApppppppprrrroooovvvveeeedddd DDDDooooccccuuuument K, 2013 edition 9
OOO NNN LLL III NNN EEE VVV EEE RRR SSS III OOO NNN
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.