O N L I N E V E R S I O N A1/2 THICKNESS OF WALLS IN CERTAIN SMALL BUILDINGS Diagram 18 Wall thickness See para 2C38 (ii) Size and location of openings The only other openings permitted in a building or annexe are for windows and a single leaf door. One or two major openings not more than 2.1m The size and location of these openings should in height are permitted in one wall of the building be in accordance with Diagram 17. or annexe only. The width of a single opening or the combined width of two openings should not (iii) Wall thickness and recommendations exceed 5m. for piers The walls should have a minimum thickness of 90mm. Approved Document A Structure O N L I N E V E R S I O N 33