Skip to content

England · Statutory guidance

Structure: Approved Document A

Guidance on structural loading, foundations, walls, floors, roofs and disproportionate collapse.

Structure
Open original PDF at page 7

Source wording and page order preserved. Drawings and table layouts remain available in the original PDF.

O N L I N E V E R S I O N A1/2 LOADING AND GROUND MOVEMENT The Requirements This Approved Document deals with the following Requirements which are contained in the Building Regulations 2010. Requirement Limits on application Loading A1. (1) The building shall be constructed so that the combined dead, imposed and wind loads are sustained and transmitted by it to the ground: (a) safely; and (b) without causing such deflection or deformation of any part of the building, or such movement of the ground, as will impair the stability of any part of another building. (2) In assessing whether a building complies with sub-paragraph (1) regard shall be had to the imposed and wind loads to which it is likely to be subjected in the ordinary course of its use for the purpose for which it is intended. Ground movement A2. The building shall be constructed so that ground movement caused by: (a) swelling, shrinkage or freezing of the subsoil; or (b) land-slip or subsidence (other than subsidence arising from shrinkage), in so far as the risk can be reasonably foreseen, will not impair the stability of any part of the building. Approved Document A Structure O N L I N E V E R S I O N 5

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.