CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors. Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2. Table 404.2.4.2 Maneuvering Clearances at Doorways without Doors or Gates, Manual Sliding Doors, and Manual Folding Doors Minimum Maneuvering Clearance Parallel to Doorway (beyond Approach Direction Perpendicular to Doorway stop/latch side unless noted) From Front 48 inches (1220 mm) 0 inches (0 mm) From side1 42 inches (1065 mm) 0 inches (0 mm) From pocket/hinge side 42 inches (1065 mm) 22 inches (560 mm)2 From stop/latch side 42 inches (1065 mm) 24 inches (610 mm) 1. Doorway with no door only. 2. Beyond pocket/hinge side. Figure 404.2.4.2 Maneuvering Clearances at Doorways without Doors, Sliding Doors, Gates, and Folding Doors D1e6p0artment of Justice 2010 Standards: Titles II and III - 123