404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be
provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects
more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of
the door or gate.
Advisory 404.2.4.3 Recessed Doors and Gates. A door can be recessed due to wall
thickness or because of the placement of casework and other fixed elements adjacent to the
doorway. This provision must be applied wherever doors are recessed.
Figure 404.2.4.3
Maneuvering Clearances at Recessed Doors and Gates
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering
clearances shall comply with 302. Changes in level are not permitted.
EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted.
2. Changes in level at thresholds complying with 404.2.5 shall be permitted.
404.2.5 Thresholds. Thresholds, if provided at doorways, shall be ½ inch (13 mm) high maximum.
Raised thresholds and changes in level at doorways shall comply with 302 and 303.
EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled
edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5.