CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL 407.2.2.1 Visible and Audible Signals. A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. EXCEPTIONS: 1. Visible and audible signals shall not be required at each destination- oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car designation information. 2. In existing elevators, a signal indicating the direction of car travel shall not be required. 407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2-½ inches (64 mm) minimum measured along the vertical centerline of the element. Signals shall be visible from the floor area adjacent to the hall call button. EXCEPTIONS: 1. Destination-oriented elevators shall be permitted to have signals visible from the floor area adjacent to the hoistway entrance. 2. Existing elevators shall not be required to comply with 407.2.2.2. Figure 407.2.2.2 Visible Hall Signals 407.2.2.3 Audible Signals. Audible signals shall sound once for the up direction and twice for the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel. Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum. The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. EXCEPTIONS: 1. Destination-oriented elevators shall not be required to comply with 407.2.2.3 provided that the audible tone and verbal announcement is the same as those given at the call button or call button keypad. 2. Existing elevators shall not be required to comply with the requirements for frequency and dB range of audible signals. D1e7p2artment of Justice 2010 Standards: Titles II and III - 135 Titles II and III - 2010 Standards - 106

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.