CHAPTER 4: ACCESSIBLE ROUTES TECHNICAL
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is
provided, existing car operating panels shall not be required to comply with 407.4.7.
407.4.7.1 Buttons. Car control buttons shall comply with 407.4.7.1.
407.4.7.1.1 Type. Control buttons shall be identified by tactile characters complying with
703.2.
407.4.7.1.2 Location. Raised character and braille designations shall be placed immediately
to the left of the control button to which the designations apply.
EXCEPTION: Where space on an existing car operating panel precludes tactile markings
to the left of the controls, markings shall be placed as near to the control as possible.
407.4.7.1.3 Symbols. The control button for the emergency stop, alarm, door open, door
close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table
407.4.7.1.3.
Table 407.4.7.1.3 Elevator Control Button Identification
Control Button Tactile Symbol Braille Message
Emergency Stop
“ST”OP Three cells
Alarm
AL“AR”M Four cells
Door Open
OP“EN” Three cells
Door Close
CLOSE Five cells
Main Entry Floor
MA“IN” Three cells
Phone
PH“ONE” Four cells
407.4.7.1.4 Visible Indicators. Buttons with floor designations shall be provided with visible
indicators to show that a call has been registered. The visible indication shall extinguish
when the car arrives at the designated floor.
D1e7p8artment of Justice 2010 Standards: Titles II and III - 141
Titles II and III - 2010 Standards - 112
Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.