TECHNICAL CHAPTER 4: ACCESSIBLE ROUTES 407.4.7.2 Keypads. Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button. The number five key shall have a single raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 703.3.1. 407.4.8 Car Position Indicators. Audible and visible car position indicators shall be provided in elevator cars. 407.4.8.1 Visible Indicators. Visible indicators shall comply with 407.4.8.1. 407.4.8.1.1 Size. Characters shall be ½ inch (13 mm) high minimum. 407.4.8.1.2 Location. Indicators shall be located above the car control panel or above the door. 407.4.8.1.3 Floor Arrival. As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. EXCEPTION: Destination-oriented elevators shall not be required to comply with 407.4.8.1.3 provided that the visible indicators extinguish when the call has been answered. 407.4.8.1.4 Destination Indicator. In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations. 407.4.8.2 Audible Indicators. Audible indicators shall comply with 407.4.8.2. 407.4.8.2.1 Signal Type. The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop. EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes or is about to stop at a floor served by the elevator shall be permitted. 407.4.8.2.2 Signal Level. The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator. 407.4.8.2.3 Frequency. The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum. 407.4.9 Emergency Communication. Emergency two-way communication systems shall comply with 308. Tactile symbols and characters shall be provided adjacent to the device and shall comply with 703.2. 142 - 2010 Standards: Titles II and III Department of Jus1ti7c9e

Edition and local adoption determine which requirements apply. Use the publisher’s document for the complete clauses, diagrams and amendments.